Publication Summary

Title

Lakewood/Plaza Cleaners July 31, 1996

Month-Year PublishedMarch 1997
Online Availability
View this publication in Acrobat PDF format
2161 kilobytes,  requires version 4.0 or later of Adobe Acrobat Reader Software  get Acrobat Reader
Short Description

This document is one in a series describing the results of ground water sampling at Lakewood/Plaza Cleaners. Ecology has conducted semi-annual ground water sampling at the site since 1991. The objective of this sampling is to collect ground water quality data for the Toxics Cleanup Program to evaluate the effectiveness of Lakewood supply wells H1 and H2 to contain and remove contaminated ground water caused by Plaza Cleaners. Samples were collected on July 31, 1996 from one municipal well (H2) and five monitoring wells: MW-16A, MW-20A, MW-20B, MW-27, and MW-33. All samples were analyzed for volatile organics (VOAs).

(Also see abstract below)
Publication Number97-312
Author(s)Marti, P.
Print Availability
Request from the program.
Number of pages 10 pp. + app (38 total)
Keywords cleanup, Ground Water, groundwater, laboratory, model, Model Toxic Control Act, quality assurance, toxic, toxics, water, water quality, wells
Subject Waterbodies
Clover Creek
map of Washington state showing locations of subject waterbodies
Abstract Long Description

This document is one in a series describing the results of ground water sampling at Lakewood/Plaza Cleaners. Ecology has conducted semi-annual ground water sampling at the site since 1991. The objective of this sampling is to collect ground water quality data for the Toxics Cleanup Program to evaluate the effectiveness of Lakewood supply wells H1 and H2 to contain and remove contaminated ground water caused by Plaza Cleaners. Samples were collected on July 31, 1996 from one municipal well (H2) and five monitoring wells: MW-16A, MW-20A, MW-20B, MW-27, and MW-33. All samples were analyzed for volatile organics (VOAs).

Wells MW-20B and MW-16A are the only wells in which PERC, TCE and cis-1,2-DCE concentrations continue to be elevated. Concentrations is well MW-20B were 387 mg/L, 7.6 mg/L, and 15 mg/L, respectively. PERC and cis-1,2-DCE concentrations in MW-16A were 43 mg/L and 1.9 mg/L, respectively. PERC was detected below the practical quantitation limit of 1 mg/L in wells MW-20A and H2, as well as for TCE in MW-16A. Model Toxic Control Act (MTCA) cleanup levels were exceeded for tetrachloroethene (5.0 mg/L) in MW-20B and MW-16A and for trichloroethene (5.0 mg/L) in MW-20B. Overall, concentrations are similar to those reported in previous sample rounds.